Quesco CC Print
PDF
TECHNICAL DATA - DIMENSIONS IN MM
Size
A
C
D
E
Filed Weight (kgs)
GD2-PRI
(Kg m2)
Oil Qty Ltr.
8.00
237.00
42.00
35.00
165.00
13.20
0.246
1.70
9.25
268.00
48.00
48.00
194.00
17.70
0.332
2.60
10.50
308.00
48.00
48.00
210.00
22.20
0.540
3.70
11.50
333.00
60.00
55.00
232.00
35.00
0.750
4.60
12.75
368.00
60.00
55.00
262.00
41.00
1.380
6.80
14.50
419.00
80.00
70.00
287.00
57.60
2.530
10.20
16.25
454.00
80.00
70.00
335.00
74.00
4.200
13.60
17.75
502.00
85.00
76.00
354.00
106.00
6.400
17.00
20.00
578.00
85.00
76.00
390.00
142.00
11.500
26.00
23.00
660.00
110.00
100.00
457.00
207.00
23.000
40.00
26.00
749.00
110.00
100.00
492.00
0.27
38.000
57.00
29.00
838.00
130.00
115.00
552.00
358.00
65.000
78.00
32.00
914.00
150.00
115.00
587.00
520.00
95.000
106.00
36.00
1032.00
150.00
150.00
626.00
678.00
182.000
136.00
41.00
1162.00
150.00
150.00
660.00
948.00
316.000
205.00
Size
Max. Operating kW rating at various motor speeds

580
720
960
1450
8.00
-
0.29
0.69
2.36
9.25
0.31
0.60
1.42
4.88
10.50
0.59
1.13
2.68
9,21
11.50
0.90
1.83
4.35
14.01
12.75
1-64
3.13
7.53
26.10
14.50
3.00
5.67
13.42
46.20
16.25
5.44
10.44
24.76
75.00
17.75
8.13
15.51
37.29
120.00
20.00
15.73
30.13
75.00
151.00
23.00
30.00
56.70
130.00
275.00
26.00
58.20
112.00
210.00
455.00
29.00
101.00
187.00
340.00
615.00
32.00
155.00
271.00
420.00
837.00
36.00
273.00
345,00
725.00
-
41.00
410.00
634.00
1000.00
-
TYPE FCU SELECTION TABLE
The chart maybe used for selecting a type FCU fluid coupling. It shows maximum operating power ratings for approved application with direct-on started squirrel cage motors, and will allow 200% full load torque for starting. Selections may be different from those shown, for drives having frequent cyclic duty, very high inertia starting, or diesel engine drives, such cases should be referred to Premium Energy Transmission Ltd. Office or representative who will prepare specific proposals.
These ratings are also generally suitable for drives employing slip-ring motors; for drives using DC motors consult Premium Energy Transmission Ltd. Allow for 3 to 5% slip in fluid coupling-low to high loadings.
CONSTANT FILLINGS FLUID COUPLINGS
The type FCU fluid coupling when used in conjunction with a fixed speed motor
will give the motor a light-load start, provide smooth acceleration and ensure overload protection for the motor and driven machine. Using a fluid coupling in the drive-line often makes its possible to employ a smaller motor, because the fluid coupling will allow the motor to run quickly up to speed, where its overload capacity may be used for starting the machine.
Starting or stalling torque may be determined precisely by selection of the initial oil filling. Further adjustment, to suit drive requirements, may easily be made at site. The type FCU fluid coupling is a compact, rugged unit, the major components being aluminium alloy castings. It comprises the basic fluid coupling, diaphragm input mounting and multidisc type semi-flexible coupling on the output side. Bores and keyways may be finished to suit customer's requirements.
Fusible plugs are fitted to all except the smaller model fluid couplings to provide protection against excess temperature rise should the motor overload trip fail to operate during stall or overload conditions. Vertical applications can be catered for in most sizes.
Units are available in sixteen sizes, covering ratings from 0.1 kW to 1000kW.

Belt Conveyors   

Barking Drums

Ball Mills

Rotary Dryers

Reciprocating Pumps   

Crushers                 

Winches

Centrifuges   

Chain Conveyors  

Cranes  

Hammer Mills

Haulages   

Mixers and Agitators

Marine Transmission

SOME OF THE TYPICAL APPLICATIONS INCLUDE:
couplings and fluid drives.pdf
Couplings and Fluid Drives - Constant Fillings Fluid Couplings
Elastomeric couplings Fluid Couplings Grid and Gear couplings Couplings Type A Fluid drive Torque Limiter Constant fillings Couplings and fluid drives - Home