Quesco CC Print
PDF
Control Cable - Rubber insulation and sheath Cable for basket operation
NEW
10. CABLES FOR GRAVITY -FED COLLECTOR !N BASKET suitable for spreader connection
TRATOSCOIFLEX 300/500 V

FEATURES AND PERFORMANCES

Rated Voltage   300/500 V
Max Voltage AC 550V
AC Voltage Test      2 Kv

1 - 6x2.5 group (1)
2- Kevlar support
3 - Sheath black PCP
Part Number
Cross Section
Maximum Diameter of single Wires
Rated Voltage
Maximum Temperature of the Conductor During Operation
Maximum Temperature of the Conductor During Short Circuit
Max. Tensile Load During Installation and operation
Minimum Overal Diameter
Maximum Overal Diameter
Nominal Cable Weight

mm
mm
Uo/U
°C
°C
N
mm
mm
Kg/m
FSA701
7 X 1.5
0.21
0,6/1 kV
90
250
157
16.0
18.0
0.440
FSA121
12X1.5
0.21
0.6/1 kV
90
250
270
21.5
24.0
0.720
FSA181
18X1.5
0.21
0.6/1 kV
90
250
405
22.2
24.7
0.780
FSA241
24X1.5
0.21
0.6/1 kV
90
250
540
26.0
29.0
1.050
FSA301
30X1.5
0.21
0.6/1 kV
90
250
675
29.0
32.0
1.200
FSA361
36X1.5
0.21
0.6/1 kV
90
250
810
29.0
32.0
1.300
FSA702
7X.2.5
0.21
0.6/1 kV
90
250
262
17.8
20.3
0.540
FSA122
12X2.5
0.21
0.6/1 kV
90
250
450
24.4
27.4
0.950
FSA182
18X2.5
0.21
0.6/1 kV
90
250
675
26.0
29.0
1.100
FSA242
24x2.5
0.21
0.6/1 kV
90
250
900
30.2
33.2
1.450
FSA302
30X2.5
0.21
0.6/1 kV
90
250
1125
31.5
34.5
1.800
FSA362
36X2.5
0.21
0.6/1 kV
90
250
1350
32.0
35.0
1.900
CONTROL CABLES 0.6/1 kV according to standards VDE 0250 t.814 (as applicable)


TRATOSMART®- (N)SHTOU-JZ
TRATOSMART® - (N)SHTOU –JZK (1)
FEATURES AND PERFORMANCES
Rated Voltage   0,6/1 Kv        
Max Voltage   AC 0,7/1,2 kV   
AC Voltage Test   3,5 kV
1 -Tinned flexible conductor CI. 5 VIDE 0295
2 - EPR insulation type 3GI3
3- inner sheath PCP
4 -Antitorsional protection
5- Outer sheath 5GM3
Working Temperature


Travel Condition
Suitable




mt/ minute max
Fixed installation
-350°C

Festoon
180
In Operation
-25°C to + 60°C

Monospiral Reel
120

-40°C (K Type) to
+ 50°C



Working Temperature


Max Temperature on conductor
      
+90°C

In Operation
-20°C to + 60°C
Control cable - Rubber insulation and sheath Cores individually screened
Reduced dimensions - see data sheet
electrical Cables.pdf
Electrical Cables- Rubber Isolation and Sheath
Part Number
Cross Section
conductor
Insulation Material
Finished Cable
Approx Minimum Bending Radius
Single wire max diameter
Nominal diameter
DC Resistance
at 20 °C Max
Maximum Overal Diameter
Weight
Maximum Tensile Load

mm2
mm
mm
ohm/km

mm
Kg/m
N
mm
FCA362
36X2.5 (6X6X2.5)
0.16
2
8.21
EPR 90OC
39.5
2.600
1800
700
FCA422
42X2.5 (7X6X2.5)
0.16
2
8.21
EPR 90OC
46.5
3.350
2100
700
FCA362
54X2.5 (9X6X2.5)
0.16
2
8.21
EPR 90OC
52.0
4.000
2700
700